HomeELT TesterBT-611ELT SELT AF/APAbout usContacts

ELT Tester
The ELT Tester is designed to decode and display the encoded message from a 406 MHz Cospas-Sarsat Emergency Locator Transmitter. The tester can be connected directly to the ELT or monitored "over the air" using the supplied whip antenna. The tester will decode any 406 MHz aviation protocol for ELT's.

A complete measurement solution. Measures all Cospas-Sarsat frequency channels and decodes all Cospas-Sarsat protocols. Measures 406 MHz parameters, 121.5 MHz parameters modulation, and the in-band 406 MHz frequency spectrum. The beacon industry is demanding higher quality from 406 beacons and is implementing more thorough periodic testing. Beacon Testers that only decode the 406 message are not suitable to meet the increasing demands from the industry to ensure the beacons are indeed operating properly. The ELT Tester provides thorough beacon measurement capabilities.

Features and characteristics:

1.Tester provides measurement of 406MHz frequency carrier with accuracy +/-500Hz.
NOTE: The operation frequency range of the tester is expanded to 406018…406048kHz and is divided on six subranges.The default subrange is 406023…406028kHz. The operation ELT frequency should be in subrange.
2. Tester provides the audio control of sweep-tone of 121500+/-10kHz carrier frequency.
3. Tester provides the reception and decoding of emergency message either in HEX format (separately 1-112 bits, 26-108 bits, 26-85 bits, 113-144 bits), or in text format with main message's parameters. Besides, the BCH code is calculated to be compared with accepted.
4. Tester measures the positive and negative phase deviation of modulated signal with accuracy upto +/-2,8 degrees .
5. Tester provides estimation of message transmission total time with accuracy upto 0.2% and preamble duration with accuracy of +/-0.2%.
6. Tester provides measurement of received signal level on 406MHz frequency in range of 19...40dBm or 0,08...10W with accuracy +1/-5dB.
7. Tester provides measurement of received signal level on 121.5MHz frequency in range of 13...20dBm or 20...100mW with accuracy +/-3dB.
8. Tester allows to carry out the measurements either by HF-cable or by means of external antenna in distance of 1.5..4m; the recommended distance is 2-3 meters.
9. The HF input resistance is 50 +/-1,5Ohm.
10. Tester allows to save upto 10 measurement results in its memory.
11. The total time of one measurement cycle is not more then 2 minutes.
12. Tester is power supplied either by external 5,2…9DCV source or by 4 AAA type 1.5V batteries.
13. Current consumption:
" in safe mode without LCD highlighting - not more then 80 mA
" in safe mode with LCD highlighting - not more then 120 mA
" in measurement mode with LCD highlighting - not more the 200 mA .
14. The estimated total time of operation supplied by batteries is 6 hours.
15. Tester is automatically turned off in 15 minutes without its usage.
16. Tester displays the voltage of internal batteries with accuracy upto 5%.

The complete set of ELT tester includes:

- Main unit
- Connection cables
- ААА type 6V batteries (4 units)
- Software
- 6-9V power supply unit
- English manual

Following models of ELT were succesfully tested by ELT Tester:

Manufacturer: ELTA
C/S No ELT Model
131 ADT406 AF/AP
020 A06

Manufacturer: Air Precision
C/S No ELT Model
074 ELT 96
074 ELT 96 S
074 ELT 97

Manufacturer: Techtest Limited
C/S No ELT Model
097 ELT503-1
097 ELT503-3
103 ELT503-12
103 ELT503-2

Manufacturer: SERPE-IESM
C/S No ELT Model
Kannad 406 AF
Kannad 406 AF-H
105 Kannad 406 AP
105 Kannad 406 AS
091 Kannad 406 ATP
101 Kannad 406 XS
138 Kannad 406 XS-2

Manufacturer: Honeywell
C/S No ELT Model
124 RESCU 406 AF
RESCU 406 S (Survival)

Manufacturer: Artex
C/S No ELT Model
112 B406-4
112 C406-1
112 C406-2
135 C406-N
126 G406-4

Manufacturer: Acr
C/S No ELT Model
074 AeroFix 406
 
ELT Tester software


readmore

Download ELT Tester Manual



Advertising in pdf
Copyright Musson Marine Ltd, 2006