Beacon Simulator BG-105
Technical description
Operational Modes
Up to five independent Beacons (Channels) transmitted simultaneously. Operational Modes is as follows:
- Continuous Wave (CW)
- Continuous Message (CM)
- Burst – deterministic repetition period
- Burst – random repetition period
- Burst – External Triggered
- Burst – Manual Triggered
Individual Beacon-Transmitter Parameters:
Digital Message Generator
- Repetition Period: 0,5…65 s, Resolution - 0,001 s
- Relative Message Offset: 0…16 s, Resolution - 0,1 s
- Total Time Transmission: 435.6…444.4 ms and 514.8…525.2 ms, Resolution - 0,1 ms
- Unmodulated Carrier Time: 158.4…161.6 ms, Resolution - 0,1 ms
- Bit Rate: 400bps ±1%
Modulator and 406 MHz Transmitter
- Frequency: 406.000000…406.100000 MHz, Resolution - better than 1 Hz
- Frq. short temperature variation: better than 2*E-09 (2 ppb)
- Frq. mean slope: better than 1*E-09 (1 ppb)
- Residual frequency variation: better than 3*E-09 (3 ppb)
- RF Output signal attenuation: 0…45 dB (0…85.5 dB max), Resolution - 0.5 dB
- Phase Deviation: 0.9…1.3 rad, Resolution - 0.1 rad
- Modulation Rise/Fall Time: 50…250 us, Resolution: 1 us
- Modulation symmetry: ≤ 0.05
- Burst-switch attenuation: ≥ 45 dB
RF Output
Output Connector: SMA Female
Power Level (when 5 simultaneous beacons at max power): 0dBm ±1dB
Output Impedance: 50 Ω
VSWR: <1.3
Safety and EMC
Safety class: I (EN61010-1)
EMC: Complies with EN61326 Class B.
Power Supply
Power supply: 115/230V ± 10%, 50/60 ±3 Hz
Power consumption: <10 W
Operating environmental conditions
Operating temperature: +5°C…+40°C
Storage temperature: -20°C…+40°C
Max. rel. humidity: 40%...60% (non condensing)
Transport and storage environmental conditions
Temperature: -40°C to +60°C
Humidity: 5% to 95% (non-condensing)
Pressure: equivalent up to 15km altitude
Mechanical
Dimensions (W x H x D): 485 x 132 x 405 (mm)
Weight: 8 kg